Moog ACV with CANopen bus interface
7 Servo valve functions
Function generator
B99224-DV018-D-211, Rev. A, October 2018
265
7.18.3.2 Object 0x3102: Square output (Trigger signal)
This signal has the same frequency as the function generator output signal but is fixed to a rectangular shape
and with a magnitude of 32767 increments with no offset.
Value description
Figure 157: Trigger signal
FunctionGenerator
Index
Sub-index
Parameter name
Data type
Access
Persistence
Value range
Default
0x3102
0
FunctionGenSquareOutput
INT16
ro
-
INT16
None
T=1/f
t
32768
-32767
16384
-16384
<FunctionGenSquareOutput>
(0x3102)
f = <FunctionGenFrequency> (0x3103) * #Factor# [Hz]
M = 32768 [Inc.] fixed
M