Moog ACV with CANopen bus interface
8 Diagnostics
Fault reaction
B99224-DV018-D-211, Rev. A, October 2018
271
8.1.3 Fault reaction type
The fault reaction parameter <FaultReactionType> (0x2830) can be used to configure the fault behavior for
each fault code.
8.1.3.1 Object 0x2830: Fault reaction type
The fault reaction for each fault event can be configured by selecting different fault reaction types 0 to 3. The
reaction 127 (non-removable error) is predefined. This fault reaction type cannot be changed.
121
0x79
Reserved
4
24
122
unused unused
122
0x7A
Reserved
4
25
123
unused unused
123
0x7B
Reserved
4
26
124
unused unused
124
0x7C
Reserved
4
27
125
unused unused
125
0x7D
Reserved
4
28
126
unused unused
126
0x7E
Reserved
4
29
127
unused unused
127
0x7F
Reserved
4
30
128
unused unused
128
0x80
Reserved
4
31
129
unused unused
Fault code
Fault description
Dword
<FaultReactionType>
(0x2830)
Dec.
Hex.
Num
Bit
Sub-
Index
Value
range
De-
fault
Table 112: Possible fault codes (part 4 of 4)
To get the ndex of the fault reaction type <FaultReactionType> (0x2830), the fault code must be
incremented by 101.
FaultReaction
Index
Sub-index
Parameter name
Data type
Access
Persistence
Value range
Default
0x2830
1…128
FaultReactionType
INT8
rw
Y