Moog ACV with CANopen bus interface
2 Access over CANopen
CANopen communication protocols
B99224-DV018-D-211, Rev. A, October 2018
24
2.8.3.2.4 Object 0x1603: 4th RxPDO mapping
Fourth RxPDO mapping.
The mapping of this PDO is predefined as default mapping for a standard p/Q-control valve. It maps the
<ControlWord> (0x6040), the <SplSetpoint> (0x6300) and the <PrsSetpoint> (0x6380).
Value description
2.8.3.3 RxPDO counter
The received process data objects (RxPDOs) are counted using the object 0x3012 separately for every four
PDO channels. On each power on the counters will be initialized with zero.
2.8.3.3.1 Object 0x3012: RxPDO counter
2.8.3.4 TxPDO protocol configuration (COB-ID: 0x180, 0x280, 0x380, 0x480)
The transmit process data object (TxPDO) protocol must be configured and the transmit values must be
mapped to the local parameters. Four transmit TxPDO channels are available. The transmission of the PDOs
can be triggered by following events:
• Event timer elapsed.
• Synchronization (SYNC) telegram received.
Every event forces a PDO transmission. More than one event type can be active at the same time.
CANopen
Index
Sub-
index
Parameter name
Data
type
Access
Persis-
tence
Value
range
Default
0x1603
0
RPdo4_NumberOfMappedApplicParaInPdo
UINT8
rw
Y
0…8
3
0x1603
1
RPdo4_ApplicPara1
UINT32
rw
Y
UINT32
0x60400010
0x1603
2
RPdo4_ApplicPara2
UINT32
rw
Y
UINT32
0x63000110
0x1603
3
RPdo4_ApplicPara3
UINT32
rw
Y
UINT32
0x63800110
0x1603
4
RPdo4_ApplicPara4
UINT32
rw
Y
UINT32
0
0x1603
5
RPdo4_ApplicPara5
UINT32
rw
Y
UINT32
0
0x1603
6
RPdo4_ApplicPara6
UINT32
rw
Y
UINT32
0
0x1603
7
RPdo4_ApplicPara7
UINT32
rw
Y
UINT32
0
0x1603
8
RPdo4_ApplicPara8
UINT32
rw
Y
UINT32
0
CANopen
Index
Sub-
index
Parameter name
Data
type
Access
Persis-
tence
Value
range
Default
0x3012
1
RPdo1_Counter
UINT32
rw
N
UINT32
0
0x3012
2
RPdo2_Counter
UINT32
rw
N
UINT32
0
0x3012
3
RPdo3_Counter
UINT32
rw
N
UINT32
0
0x3012
4
RPdo4_Counter
UINT32
rw
N
UINT32
0