Igloo Dome
Power 120VAC .
50/60 H
2.
300 WATTS.
Tools Required: Phillips Head Screwdriver.
Ceiling Support Wires(14 AWG wire min.)
Energía 120VAC.
50/60 H
2
.
300 VATIOS.
Las herramientas requirieron: Destornillador principal
Phillips.
Alambres de la ayuda del techo
(14 de alambre del AWG Min.)
Puissance 120VAC.
50/60 H
2
.
300 WATTS.
Outils requis : Tournevis phillips.
Fils de soutien de plafond (14 de fil d'A.W.G. mn)
Energie 120VAC.
50/60 H
2
.
300 WATT.
Werkzeuge erfordert: Kreuzkopfschraubenzieher.
Decken-Stützdrähte (14 AWG-Lehredraht Min.)
Poder 120VAC.
50/60 de H2.
300 WATTS.
As ferramentas exigiram: Chave de fenda principal de
Phillips.
Fios da sustentação do teto
(14 de fio Calibre de diâmetro de fios Min.)
Potere 120VAC.
50/60 di H2.
300 WATT.
Gli attrezzi hanno richiesto: Cacciavite phillips. Legare
di sostegno del soffitto
(14 del legare dell'AWG min.)
!!
Electrical Specifications
Français
Deutsch
Italiano
Portuguese
Español
English
Mechanical Options
1. Air flow sensor available to be combined with camera output systems
to monitor the effectiveness of air filter. If improper air flow is detected,
sensor will send alarm. If user by passes air flow sensor, air filter should
be changed approximately every 6 months (depending on monitoring
environment).
2. The Igloo Dome incorporates an automatic cool-down safety
precaution system which deactivates the power of both the camera and
cooling system when internal temperatures exceed 167°F (75°C). Once
safe operating conditions resume, the camera and cooling system will
reactivate.
3. Condensation and water run-off is a by product of the Igloo Dome's
cooling system. To prevent damage to the internal electrical
components, the Igloo Dome consists of a water run-off hose, located
underneath the optical dome. Please use caution that small amounts of
water accumulation will be present directly underneath the Igloo Dome,
resulting in slippery conditions.
* A 50/50 blend of propylene glycol and water has a freezing point of
-26°F. If lower temperature protection is required, it can readily be
attained by increasing the concentration of propylene glycol Antifreeze -
for example; a 60/40 blend of Antifreeze and water gives antifreeze
protection to -54°F.