Automatic inertia detection
Once the safety notice window has been confirmed, the wizard is activated to
determine the mass inertia. When it has been successfully determined, a green tick
(check-mark) is displayed.
See also Section "Mass inertia detection" on page 108 as well.
Enhanced >>
When you click the “Enhanced >>" button, the wizard provides you with support in
setting up the current, torque, speed and position controllers. If further optimization is
required, the controller buttons route you to more detailed dialog boxes.
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD Servo Drive - Device Help
23
3 Initial commissioning
3.3 Motor
Fig. 3.5: “Initial Commissioning - Motor data and control settings” dialog box
You can click on the "
Select motor dataset
" button to select a motor from
Moog.
If you want to use a different motor, you can configure it by clicking on the
"
Manual motor settings
" button. For details see
Section
If you need to configure the temperature and current monitoring mechanism,
click on the "
Motor protection
" button. For details see
To configure a motor brake, click on the "
Motor brake
" button. For
details,
see
Section