NOTE
If the analog inputs are used as feedback for control circuits, they
will be sampled every 125 µs.
If functions are assigned to the analog inputs using
P 109
[0]/P 110[0]
, the inputs will be sampled every 1 ms.
By switching parameter
P 301[0] - CON_REF_Mode
from PG(0)
to IP(1) mode, an analog input can be used as a "fast input" (e.g.
Touch probe). The sampling time set in
P 306[0] - CON_IpRefTS
for the interpolation takes effect.
9.4.5 Wire break monitoring
P 399 - CON_ANA_WireBrk_Th is used to define the wire break monitoring
threshold (in V) (parameter index [0] for ISA00, parameter index [1] for ISA01). If the
voltage falls below this limit an error message is generated. The error response can
be configured using P 30[52] - Reac_Ana (see Section Error re
ID
Index Name
Unit Description
399
CON_ANA_WireBrk_Th
Analog inputs: Wire beak detection limits
399
0
ISA00
V
Cable break detection limit for analog input
ISA00
399
1
ISA01
V
Cable break detection limit for analog input
ISA01
Table 9.13: “Wire break monitoring” parameters
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD
Servo
Drive -
Device
Help
24
7
9 Input/Output settings
9.5 Analog outputs (option for MSD Servo Drive
only)
Fig. 9.10: “Function selection of optional analog outputs (option)” screen
If your MSD Servo Drive features the "C 2AO" technology option, you will
have two analog outputs available, enabling you to output values from the drive
using analog signals. The function selector offers nine variables for selection for
each output. These variables can be filtered, scaled, and assigned an offset.