11 Alarm & warnings
Error
No.
Error location
Error handling
Emergency
code
CiA 402
(1) EncCH1Init_Sincos_
Lines
SinCos:
Plausibilisierung
‚Lines‘ aus PRam_
ENC_CH1_Lines.
Kanal 1 Initialisierung,
SinCos: Strichzahl
des SinCos-
Absolutgebers muss
aus 2^n sein
0x7305
(2) EncCH1Init_Sincos_
ABSquareSum
SinCos: Kanal 1
Initialisierung,
SinCos:
Zeitüberschreitung
bei Berechnung der
AB-Quadratsumme.
0x7305
(3) EncCH1Init_Sincos_
EncObs
SinCos:
Geberüberwachung
SinCos
0x7305
(4) EncCH1Init_
EnDat2.1_NoEnDat2.1
EnDat2.1: No
EnDat2.1 encoder
(encoder may be SSI.)
0x7305
(5) EncCH1Init_
EnDat2.1_Line5
EnDat2.1: Plausibility
check 'Lines' from
encoder Endat 2.1:
Error while reading
from 'Lines'.
0x7305
Table 11.8: Error list (continue)
Error
No.
Error location
Error handling
Emergency
code
CiA 402
(6) EncCH1Init_
EnDat2.1_Multiturn
EnDat2.1: Plausibility
check 'Multiturn' from
encoder Endat 2.1:
Error while reading
from ‘Multiturn'
0x7305
(7) EncCH1Init_
EnDat2.1_Singleturn
EnDat2.1: Plausibility
check 'Singleturn'
from encoder
0x7305
(8) EncCH1Init_
EnDat2.1_CrcPos
EnDat2.1: CRC error
position transfer
0x7305
(9) EncCH1Init_
EnDat2.1_CrcData
EnDat2.1: CRC error
data transfer
0x7305
(10) EncCH1Init_
EnDat2.1_WriteToProt
EnDat2.1: An attempt
was made to write to
the protection cells in
the encoder!
0x7305
(11) EncCH1Init_
EnDat2.1_SscTimeout
EnDat2.1: Timeout on
SSC transfer
0x7305
(12) EncCH1Init_
EnDat2.1_
StartbitTimeout
EnDat2.1: Timeout, no
start bit received from
encoder
0x7305
(13) EncCH1Init_
EnDat2.1_PosConvert
EnDat2.1: Position
data not consistent
0x7305
(14) EncCH1Init_SSI_
Lines
SSI: Plausibility check
'Lines' from encoder
0x7305