MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD
Servo
Drive -
Device
Help
2
8
2
11 Alarm & warnings
Error
No.
Error location
Error handling
Emergency
code
CiA 402
(31) EncCH1Init_
Hiperface_Response_
Tec
HIPERFACE®:
Response with error
bit: Status returns
technology or process
error
0x7305
(32) EncCH1Init_
Hiperface_Response_
None
HIPERFACE®:
Response with error
bit: Status returns no
error
0x7305
(33) EncCH1Init_
Hiperface_Status_Com
HIPERFACE®: Status
telegram reports
communication error
0x7305
(34) EncCH1Init_
Hiperface_Status_Tec
HIPERFACE®: Status
telegram returns
technology or process
error
0x7305
(35) EncCH1Init_
Hiperface_TypeKey
HIPERFACE®: Type
identification of
encoder unknown
0x7305
(36) EncCH1Init_
Hiperface_WriteToProt
HIPERFACE®: An
attempt was made to
write to the protection
cells in the encoder!
0x7305
(37) EncCH1Init_TTL_
TTL: Control PCB
does not support TTL
evaluation
0x7305
IncompatibleHardware
Table 11.8: Error list (continue)
Error
No.
Error location
Error handling
Emergency
code
CiA 402
(38) EncCH1Init_
EnDat2.1_PositionBits
EnDat2.1: Plausibility
check 'Position Bits'
from encoder
0x7305
(39) EncCH1Init_
EnDat2.1_TransferBits
EnDat2.1: Plausibility
check 'Transfer Bits' of
transfer
0x7305
(40) EncCH1Init_Np_
NominalIncrement
NP: Plausibility check
"Lines" and 'Nominal-
Increment'
0x7305
(41) EncCh1Init_
Endat21_Common
EnDat2.1: Interface
general error
0x7305
(42) EncCh1Init_SSI_
Common
SSI: Interface general
error
0x7305
(43) EncCh1Init_
Sincos_Common
SinCos: Interface allg.
Fehler
0x7305
(44)
LinMot: Common
error
(45)
The internal multi-turn
resolution is too low to
process ENC_CH1_
MTBase correctly.
(47)
EnDat22: Common
error