4.  Genesis Comms Setup

The Genesis software package from Tritech allows the control, configuration and display of Tritech imaging and 
survey sensor data from within a single software environment.  The Following section will guide you through the 
process of setting up your system to communicate with your chosen devices.

4.1  Main GUI window

Devices are automatically added into Genesis as they 
are connected to the system via  the Ethernet or Tritech 
USB Adapter (720im).
A Tritech SCU (Surface Control Unit) or a Tritech Seahub 
is required when connecting devices using the ARCNET 
communications protocol.
The main window area will display the default output 
configuration for the specific devices you connect. 
The image to the left shows the default device window 
layout for a Gemini 720ik sonar which is similar for the 
other Gemini devices.

4.2  Ethernet Protocol Settings 

As standard all Ethernet enabled Tritech Sensors are set in the IP range of 

192.168.2.XXX

 with a subnet mask 

of 

255.255.255.0

. It is therefore necessary to configure the host network to the same IP address range as the 

sensors being connected. This can be setup in the following way.

• 

Open the network and sharing centre in Windows.

• 

Double click on the Ethernet connection.

• 

Choose properties in the pop-up dialogue.

• 

Double click the text that says “TCP/IPv4”.

• 

Check “Use the following IP address”.

• 

Set the IP address to 192.168.2.50 

• 

Set the subnet mask to 255.255.255.0

To avoid IP conflict and issues, make sure that each device on the network has a unique IP address. The addresses 
xxx.2.16, xxx.2.17, xxx.2.200, xxx.2.201 are reserved by the system so do not set to these. Make sure the option to  
“Obtain an IP address automatically” is disabled.

4.3  Windows  Firewall Settings

Check your anti-virus settings. Firewalls may stop the repetitive, high data 
rate sonar imagery packets and prevent the broadcast message.
Occasionally a firewall may allow the broadcast message but stops the 
high data rate from the sensor believing it to be a denial of service attack.
If this is the case, navigate to “Allowed Apps” in windows and add 
permissions to the firewall settings for Genesis Software.

Note

When using Ethernet, V7 cables must be 
installed on your system

Summary of Contents for Tritech Super SeaKing V7

Page 1: ...Outstanding Performance in Underwater Technology A Moog Inc Company Super SeaKing V7 Sonar Product Manual Document No 0721 SOM 00001 01...

Page 2: ...This page has deliberately been left blank...

Page 3: ...s 3 A clear fault description 4 Details of any remedial action implemented Contamination If the product has been used in a contaminated or hazardous environment you must de contaminate the product and...

Page 4: ...h a discharge occurring Caution This highlights areas where extra care is needed to ensure that certain delicate components are not damaged Warning DANGER OF INJURY TO SELF OR OTHERS Where this symbol...

Page 5: ...Diagrams 11 Tritech V7 Connector 12 SeaKing Magnetic Reset 12 Software Installation 13 System Requirements 13 Genesis Software Installation 13 Software Overview 13 Windows Setup 14 Genesis Comms Setu...

Page 6: ...ognised connector With the option of Ethernet ARCNET RS232 and RS485 communications the Super SeaKing DST is simple to install on ROV AUVs of all types Utilising the latest electronics and composite t...

Page 7: ...on 325kHz 50kHz centred on 650kHz Beamwidth 20 vertical 3 0 horizontal 40 vertical 1 5 horizontal Pulse length 400 s 200 s Range 0 4m 300m 0 4m 100m Source level 210dB re 1 Pa at 1m Display Character...

Page 8: ...may lead to corrosion of the housing which may impact the performance of the system Caution Non metallic clamps are preferred when securing the Sonar however if metallic clamps are to be used they mu...

Page 9: ...ions The Super Seaking V7 is supplied with a polyurethane jacketed cable whip as standard fitted with a Tritech connector at one end Depending on the specification of the system the cable will either...

Page 10: ...k congestion As standard we Tritech set the sonar IP address to 192 168 2 17 and subnet mask to 255 255 255 0 ARCNET Serial RS232 RS485 The Super Seaking V7 Sonar can be set to form part of an ARCNET...

Page 11: ...to equipment damage not covered under the warranty conditions Note Ethernet communications require the use of V7 cables ARCNET and Serial Communications are compatible with both V7 and Standard Tritec...

Page 12: ...0 5mm 20 AWG 4 VDC Black Black 0 5mm 20 AWG 5 N C RS232 GND NC RX_P Green Red UTP 2 0 22mm 24 AWG 6 Earth RX_N Screen White UTP 2 0 22mm 24 AWG Chassis Earth Connection Screen Drain Wire Foil Screen...

Page 13: ...memory sticks Ensure any previous version of Genesis has been uninstalled and the computer restarted prior to the installation of a new version Updates and latest versions of software can also be down...

Page 14: ...en the bandwidth allocation will be shared between devices and so the bandwidth per device will drop A network switch records the MAC addresses of the devices connected so when a frame of data is rece...

Page 15: ...255 255 255 0 It is therefore necessary to configure the host network to the same IP address range as the sensors being connected This can be setup in the following way Open the network and sharing c...

Page 16: ...eft of the configuration window Selecting a device in this list will bring up the configuration and properties window for that device The General Tab shows the basic device information including the N...

Page 17: ...connected device Todothis ensurethedeviceisonline and select the device status icon in the toolbar to show its properties and select the General tab The IP Address can be adjusted and saved to the de...

Page 18: ...e be felt by other sources of impedance such as from the cable itself The diagram below shows best practice to use when installing termination resistors on an ARCNET network of Tritech International L...

Reviews: