Page 31
For HELP, call 727.573.9611
T r o u b l e s h o o t i n g
If a problem arises, you can check this list for a quick solution. If this does not
resolve your problem, please call our customer care center, at 727.573.9611.
Additional information is also available at www.PremiumLeisure.com.
Important
– Most problems can be quickly resolved by resetting the
GFCI breaker. Try this first before proceeding.
PROBLEM CAUSE
SOLUTION
Breaker trips
Wiring error
Load Neutral wire not connected to GFCI
(connected to Neutral bus)
Wrong GFCI
GFCI breaker is wrong size
Ozonator (or
blower) wet
Remove tube from ozonator (or blower) and
allow 2 days to dry out
Foamy water
Soaps, skin
oils, or
undissolved
sanitizer
particles
Close the air control valves and allow
filtration cycle to run
Add defoamer
Drain and clean your hot tub
Clean or change filters
Rinse all bathing suits before bathing
Leak
Loose
connection
Check and hand-tighten unions at heater &
pumps, or clamps on jets
Drain open
Close drain valve or replace cap
Light doesn’t
LED burnt out
Replace bulb
work
Loose wire
Check wiring harness to LED
Loose plug
Reseat J20 plug on hot tub pack
Low/no jet
Air lock
Bleed air from the system (page 28)
pressure
Dirty filter
Check and clean or replace filter
Closed jets
Open all jets by turning CCW
Closed valves
Open all T-handle shutoff valves on heater
and pumps
ACV open
Close air control valves
Low water
Fill hot tub 1” above all jets
Moved my hot
tub and
Wiring error at
GFCI
Check Neutral wiring of GFCI (see diagrams
on pages 10-18)
now it doesn’t
work
No power to
hot tub
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Nothing
works
Breaker has
tripped
Check and reset breaker. If problem
persists, check for loose electrical
connections. Check for Neutral wiring error
at GFCI.
Fuse blown
Check for blown Fuse 4 (F4) inside of spa
pack.
Pump not
running
No power to
hot tub
Reset circuit breakers on GFCI panel and
main circuit breaker panel
Summary of Contents for ML 736
Page 18: ...Page 16 For HELP call 727 573 9611...
Page 19: ...Page 17 For HELP call 727 573 9611 Figure 12 GS510SZ Board Diagram for All EXPORT Models...
Page 41: ...Page 39 For HELP call 727 573 9611 ML 736 Callouts...
Page 43: ...Page 41 For HELP call 727 573 9611 ML 844 Callouts...
Page 44: ...Page 42 For HELP call 727 573 9611 N o t e s...
Page 46: ...6101 45th St N St Petersburg FL 33714 727 573 9611...