TSM
TSM23XIP Quick Setup Guide
Requirements
•
A 24-70VDC power supply.
•
A small flat blade screwdriver for tightening the connectors (included).
•
A PC running Microsoft Windows XP, or Windows7/8/10.
•
Software: Step-Servo Quick Tuner,
•
For Ethernet models, you'll need an Ethernet cable (CAT5e or CAT6).
Step1
Step2
•
Visit www.applied-motion.com/products/software to download the Step-Servo Quick
Tuner software.
•
Install the Step-Servo Quick Tuner software on your PC.
•
Connect the drive to the PC using the appropriate programming cable.
•
For for Ethernet models a user-supplied standard (RJ45) Ethernet cable is required,
Cat 5e or 6 recommended. Please plug the cable into the COM1 connector on the
motor for configuration. The COM2 connector on the motor can be used to “daisy chain”
this motor to another motor’s COM1 port.
•
For a direct connection between the PC and TSM23, set the static IP address of
the PC to 10.10.10.11. For more details on Ethernet connections see the TSM23
hardware manual.
Connect the Power Supply
•
Connect the main power supply “+” terminal to the motor's ”+” terminal and the power supply “-” terminal to the motor's “-”
terminal using 16 to 20-gauge wire.
Be careful not to reverse the "+" and "-" wires. Reversing the connection may blow the internal fuse and void the
warranty.
RC880
V
-
V
+
Vin
+
-
Main Power Supply
24-70VDC
V
-
V
+
Vout
+
-
2
1
17
18
920-0145A
5/22/2019
•
If a regulated power supply is being used, there may be
a problem with regeneration that can be solved with the
use of an Applied Motion RC880 Regeneration Clamp.
See Applied Motion website or the Hardware Manual for
more information.
2
1
17
18