Settings
A : Distribution Settings
SLIDE RULER
Test using the slide ruler
•
This slide ruler enables you to determine the new variator index after the first flow rate test.
•
Adjust distribution settings and carry out a test according to the recommendations contained in the
preceding pages.
•
Operation:
-
Set line (1) of the variator index used for the first flow rate test on line (2), which corresponds
to the amount in kg collected in the tray during that test
-
Without moving the slide ruler discs, find the target flow rate in Kg/ha on the line (3)
-
On line (4), read the new variator index corresponding to your seed and conditions
•
After sowing one hectare, perform another verification test.