Manual Part No: 932971-01 MD Gas Convection Oven
Page 15 of 32
Manual Rev No: 1
Installation (cont.)
Gas Connection (cont.)
Ensure that all the pipes to the appliance are clean and free from swarf etc,
BEFORE
making the final
connection.
Propane Gas: Follow the same procedure as that for Natural Gas
EXCEPT
that the Gas Governor
MUST
NOT
be fitted – the Gas Supply Tank or Cylinders are already fitted with a Gas Regulator.
Leak Test
Clean off any protective film from the stainless steel panels.
AT THIS STAGE, LEAK TEST THE WHOLE SYSTEM. THE GAS SAFETY REGULATIONS
require that
ALL
connections in the gas supply line between the Gas Meter and the appliance is tested for gas leaks.
THIS MUST BE DONE BEFORE COMMENCING TO COMMISSION THE APPLIANCE.
Checking and commissioning
ALTHOUGH EVERY APPLIANCE IS TESTED AND SET BEFORE IT LEAVES THE FACTORY, IT IS
IMPORTANT THAT THE INSTALLER RE-CHECKS CERTAIN FUNCTIONS BEFORE LEAVING SITE.
CHECK THE GAS PRESSURE AT THE APPLIANCE THUS
:
The pressure test point for Ovens is located at the rear of the appliance on the inlet tee.
Connect a manometer (U Tube) to the test point. Turn on the gas supply and light the Oven. Check that
the pressure reading agrees with that stated on the Data Plate.
Go through the oven lighting procedure, as listed in the
USERS INSTRUCTIONS
, ensuring that all neon
lights work and leave the oven set to 175
°
C for 20 minutes to ensure that it heats up and that the burner
(and amber light) goes out when the temperature is reached.
SHOULD ADJUSTMENT BE NECESSARY, PROCEED AS FOLLOWS:
-
FOR PROPANE GAS, REFER TO SUPPLIER
On the gas governor: (For Single/Two Tier Ovens this is on the solenoid valve).