Manual Part No: 931764-01 MV1 Gas Griddle
- 13 –
Manual Rev No: 1
INSTALLATION
Important
Your attention is drawn to the latest
GAS SAFETY (INSTALLATION & USE) REGULATIONS 2000.
This appliance MUST be installed by a competent person in accordance with these and any other relevant
regulations. Users, too, should be aware of the regulations governing the use of gas appliances,
particularly with respect to the need for regular servicing.
Your attention is drawn to the requirement that those parts, which have been protected by the
manufacturer or his agent, are not to be adjusted by the installer.
Before Installation
Before commencing installation, remove all packaging materials from the appliance. It is suggested that
any protective film adhering to the stainless steel panels should be left on until installation is completed.
BUT THIS MUST BE REMOVED BEFORE COMMISSIONING OR OPERATING THE APPLIANCE
.
Check the appliance Data Plate (located on the rear of the flue upstand/splashback panel), to ensure that
the appliance is suitable for the gas supply available.
The Griddle can be mounted on a counter top capable of adequately supporting the weight of the
appliance, or a purpose designed stand fitted with adjustable feet to compensate for some unevenness
of the floor.
Positioning
Place the appliance in position allowing a minimum gap of 100mm (4”) at the rear and at least 150mm
(6”) between the sides of the appliance and any adjacent wall. If the appliance is being suited then please
refer to the separate instructions. The minimum distance between the hotplate and any overshelf or
ceiling constructed of a combustible material must be 1525mm (60”).
Adequate ventilation is essential for safe operation of a gas appliance. A supply of fresh air is necessary
for the correct combustion of the gas and there must be a means of exhausting the heat and the
products of combustion from the kitchen. It is recommended that the appliance be sited below a
ventilating hood, one preferably connected to an extractor system incorporating a grease filter.
Appliances are to be installed with sufficient ventilation to prevent the occurrence of unacceptable
concentrations of substances harmful to health in the room in which they are installed.