3
MAIN TECHNICAL FEATURES
MILL SPECIFICATIONS:
Please Note:
The power should be configured appropriately. Do not increase the speed of the rollers.
INSTALLATION
The seals inside the heat exchanger are removable. Seals should be replaced if there are any signs of cracking. If the heat exchanger does
not seal before the plate’s contact, the seals must be replaced otherwise, the plates may be damaged during the tightening sequence.
MOVING YOUR MILL
•
Do not allow the mill to fall over while lifting. Damage to the machine or injury can occur.
•
Ensure you lift the mill securely and only from the bottom.
•
Do not allow people under the mill while lifting. Injury or death can occur.
ELECTRICAL INSTALLATION
•
Have a qualified electrician install the controls for your mill.
•
Provide a safety shut-off near the mill that the operator can reach.
•
Provide a safety disconnect for servicing.
•
Follow all local codes and regulations.
•
Have a qualified electrician familiar with local codes wire your mill.
•
Wire a service disconnect ahead of any needed controls and your mill.
•
A safety stop switch must be located within reach of the operating position.
Your mill is supplied with a three-phase motor rated for 208-240V. The electrician will determine if Delta or Wye wiring is suitable for
your installation. See diagrams for configuring the motor for each. The electrician will determine the wire size based on your installation.
After installation, inspect the mill for proper rotation. A mill rotating backwards will not pull grain into the gap.
TIP:
If your motor spins backward, reverse U1 and V1. See the diagram.
Delta Wiring
W1
V1
U1
V2
U2
W2
U1
V1
W1
W2
U2
V2
Wye Wiring
Model:
MILL91AS-MB
MILL95AS-MB
Outer Size L x W x H (m):
700 x 620 x 1200
800 x 800 x 1600
Weight:
375 lbs.
575 lbs.
Power (kW):
1.1
.3
Fast Roller Spindle Speed (RPM):
700
700
TABLE 1
CHART1
CHART2