Operating the Autocreaser 50
Programming the machine
1.
Switch the power ‘on’ by turning the Emergency stop button clockwise
to release the safety latch. The display is now switched on.
2.
(i) Move the selection switch to the right to select
.
Setup
(ii) Move the selection switch to the right to select
.
More
(iii) Move the selection switch to the right again to select
.
More
Setting the crease positions
3.
Move the selection switch up, one click at a time, until the start up menu is displayed
Setting the batch quantity and Dwell Time
(iv) Move the selection switch down to select
.
Set Batching
(v) Rotate the selection switch clockwise or anti-clockwise to adjust the batch quantity
in increments of 5.
as shown below.
(i) Move the selection switch to the right to select
.
Setup
(ii) Move the selection switch down to select
.
Set Creases
(iii) Move the selection switch to the left to select Tens, or to the right to select
Decimals.
(iv) The Tens or Decimals (whichever has been selected) can then be adjusted by
Storing the crease positions
4.
Once the crease positions are correctly entered, they can be stored as follows.
(i) Move the selection switch up, one click at a time, until the display contains the word
More
.
(ii) Move the selection switch to the right, one click at a time, until the display contains
the word
.
Programs
rotating the Selection Switch, (clockwise to increase or anti-clockwise to decrease).
(v) Adjust all other digits for the 1st Crease position as described in steps (iii) and (iv),
(vi) Move the selection switch down to select the 2nd Crease. The second crease will
(vii) Set the 2nd Crease position as described in steps (iii) to (v) above.
Further creases can be set in this way, up to a maximum of sixteen creases.
(i.e. move the selection switch to the left to select the Tens or to the right to select
Decimals and then rotate the Selection Switch to adjust its value.
(vi) Move the selection switch down to select
Dwell Time Secs.
(Vii) Rotate the selection switch clockwise or anti-clockwise to adjust the dwell time,
in seconds, this is the period of time between each successive batch quantity.
automatically start at 0000.0. Crease positions can be set in increments of 0.1mm.
2 Creases
Program 3
Total
20
Zero
Setup
Tools
Feed
Batch Off
(iii) Move the selection switch down to select
Save Settings.
(iv) Rotate the Selection Switch to select the Program number (1 to 9).
Page 16