49
MB 200
rev.0.1UL ID01460
7.2 START PROCESSING
7.2.4 GLUE REACTIVATING PROCEDURE
CAUTION!
Wear face, hand, protection, mask suitable for using glue and
protective goggles.
The glue reactivating procedure must be carried out every time the machine is turned off by using
the END JOB procedure.
When the machine is switched on a Cleaner error appears in the glue unit. You will need to perform
the RESET GLUE procedure
01
From the processing page, hold the button
3.0
999999
50
50
999
99
99
10
130
120
10 FREE
1-30
for a few seconds to initiate the RESET GLUE procedure.
02
In this phase, the head is opened to facilitate the output of
the cleaner.
03
In this phase the machine starts the pin cleaning cycle if
the machine has been switched on recently. After cleaning
the pins the message “Wait pins cycle” disappears.
- Remove the grains from the glue head.
Press OK
The machine begins to expel the cleaner from the extruder
and charge the glue.