10. PROBLEMS - SOLUTIONS
N°
Alarms
Description
1
Machine in Emergency
The emergency stop button is pressed or one of the doors
is open.
2
Press Fault drive
The press has not reached the position in the given time.
Check the movement. Reset the alarm if it does not reset
switch off and then back on the machine waiting 2min. If
the problem persists, contact technical assistance.
3
Cart Fault drive
Verify that along the tracks of the cart there are no
obstructions or that you have cut a very thick book at high
speed.
Reset the alarm and run pre-set..
4
Milling cutter motor thermal
trip
Check and, if necessary, replace the fuse FU13.01
5
Emergency button pressed Check that the EMERGENCY stop button has not been
pressed
6
Open rear door
Close the back door
7
Top door open
Close the top door
9
Cart Encoder Error
Cart Encoder Error.
Check that there is nothing blocking the movement, reset
the alarm and run pre-set.
10
Vise encoder error
Clamp encoder error.
Check that there is nothing blocking the movement, reset
the alarm and run pre-set.
11
Glue head encoder error
Glue Head encoder error.
Check that there is nothing blocking the movement, reset
the alarm and run pre-set.
12
Cover encoder error
Cover encoder error.
Check that there is nothing blocking the movement, reset
the alarm and run pre-set.
13
Press Movement Error
The press did not reached the highest or lowest point in
the given time, possible causes: the press is blocked so it
is necessary to unlock it manually, in order to do so turn off
the machine and remove the fan hood on the motor, looking
down on it and turning it clockwise the press descends,
broken sensor (upper or lower), the press motor is broken
or the inverter is broken or switched to alarm status.
17
High Temperature Glue
Fuser
The fuser is not within the set tolerance (max. +5°C)
18
Low Temperature Glue
Fuser
The fuser is not within the set tolerance (min. -2°C)
19
Glue Head High
Temperature
The head is not within the set tolerance (max. +5°C)
20
Glue Head Low
Temperature