Operator Manual
Digibook 300
30
rev. 3.00
10
POWER ON
1) Be sure that the machine is correctly fed by air.
2) Turn on the machine turning the general switch.
3) Open the valve on the premelter
4) Close the rear inspection panel.
On display you will see:
machine in emergency
machine with cleaner
machine not in temperature
The red light is on
5) Press once the green key,
Green is blinking
Orange is on
Red is blinking
On display:
Machine with cleaner
Low temperature
6) Exit from the alarms page using the arrow, in case the machine is equipped with
the table to measure thickness, you must press “OK” to set to zero the table.
7) When the temperature icon becomes green, press the green key. The machine
sets to zero the axes.
8) Press the key “glue cleaner” to load the glue.
9) Set values for the book you are going to manufacture and press the green key.
Orange light is on, the green one is blinking
10)
Put the book in the clamp, position the cover and press the green key.
Once the book is completed, remove carefully the book and position a new cover
and a book block. The machine will start again as soon as it will have:
The book in the clamp
The cover in the nipping station
Safety photocells free