Operator Manual
Digibook 300
32
rev. 3.00
The depletion of the glue is
found in two ways:
the lack of glue on the book;
issuing at the extrusion zone
glue clear glue mixed with air
vents and glue bubbles.
When you finish the glue and
insert a new cartridge you
have to wait about 10 min
before the new glue melts.
The machine is not opera-
tional until the set tempera-
ture is reached.
Red light on
Machine in emergency with
auxiliary turned off
Red
light
blinking
Machine on cycle with warn-
ings
Red light off
Machine in emergency and
without alarms on
Orange light
on
Machine with fed auxiliary
Orange light
blinking
Auxiliaries turned on or off in
Orange light
off
Auxiliaries turned off
Green
light
on
Machine on cycle
Green
light
blinking
Machine not on cycle
Green
light
off
Machine not ready