4.11.4
Replace the Ioniser Bar
Ioniser Bar Cable
Cable Tie
Figure 4.182
The Ioniser Bar Power Cable
LH Mounting Bracket
RH Mounting Bracket
Ioniser Bar
A4 Pinch Drive
Figure 4.183
The Ioniser Bar
Mounting Bolt and Nut
Bracket screws
Figure 4.184
LH Ioniser Bar Mounting Bracket
Tools:
•
Allen Key: 3mm
•
Screwdriver: Right-angle Pozidriv No. 1
•
Spanner: 7mm, 2 x 15mm
•
Pliers: Side Cutters.