THE CONTROL POD DISPLAY
THE DIAGRAM BELOW SHOWS THE UFO DIGITAL DISPLAY. WITH THE MOTORS, FEEDER
AND AIR OFF, OPERATE THE
MODE
SWICH UNTIL THE SPACING LAMP IS
ON
. THE IN-
FORMATION IN THE DISPLAY NOW REPRESENTS:
VACUUM
- THE VACUUM ‘ON’ TIME. VARIABLE BETWEEN 25%(1/4) AND 80%(13/16) OF
THE SHEET LENGTH IN 12.5% (1/8) INCREMENTS.
GAP
- THE GAP BETWEEN SHEETS IS ADJUSTABLE, RANGING FROM 1 TO 99.
DWELL
- THE BATCH DWELL IS IN 50% (1/2) SHEET INCREMENTS FROM 50% (1/2) TO
450% (4 1/2).
TO SET A GAP BETWEEN THE SHEETS, ROTATE THE
VALUE
DIAL UPTO A VALUE OF 99.
A GAP OF 64 WILL CREATE A GAP OF 1 SHEET.
SETTING THE SHEET SPACING,
SETTING THE VACUUM ON THE SHEETS (IN
SPACING
MODE)
THE VACUUM ‘ON’ TIME CAN BE VARIED ACCORDING TO THE WEIGHT OF THE STOCK
BEING DRIVEN IN TO THE REGISTER TABLE. A VALUE OF ‘0’ REPRESENTS A SUCTION
TIME OF 25% (1/4) SHEET LENGTH, WHERE EACH INCREMENT IS EQUAL TO 6%(1/16)
OF THE SHEET. THE MAXIMUM DISPLAY IS ‘9’. OPERATE THE DIGIT SWITCH UNTIL
THE NUMBERS THAT REPRESENT THE VACUUM ARE FLASHING. USE THE VALUE DIAL TO
ADJUST THE VACUUM TIME.
SETTING THE DWELL TIME (IN
SPACING
MODE)
THE DWELL CAN BE VARIED TO ADJUST THE FEEDER INTERRUPTION TIME WHEN
BATCHING. A VALUE OF 1 IN THE
DWELL
DISPLAY PRODUCES A PAUSE EQUIVALENT TO
50% (HALF) SHEET LENGTH. A VALUE OF ‘9’ PRODUCES A PAUSE EQUIVALENT TO
450% (4 1/2) SHEET LENGTH. OPERATE THE DIGIT SWITCH UNTIL THE NUMBERS
THAT REPRESENT THE DWELL ARE FLASHING. USE THE VALUE DIAL TO ADJUST THE
DWELL TIME.
10