133
ѯԵบຣ࣊ɽʽʒʷ˂ʳ
OIL TEMPERATURE CONTROLLER
13
ѯԵบຣ࣊ɽʽʒʷ˂ʳ
OIL TEMPERATURE CONTROLLER
8
ឬ֖
8
WARNING
ίަͽഈɂǾൡಽໃɥȪɖȪȹȢȳȨȗǿ
Ensure that the power is turned OFF when performing
maintenance.
13-1
ɲɬʟɭʵʉȻѼ᎔بɁຏો
Cleaning Air Filter and Condenser
ᴹਖ਼ᬲᴻ
<Procedure>
1)
ൡಽໃɥȪɖȬɞǿ
1)
Turn OFF the main power.
2)
ɲɬʟɭʵʉɥɝ۶Ȭǿ
2)
Remove the air filter.
7
า
7
CAUTION
ʟɭʵʉȟຣ࣊ʅʽɿȾऀȶȞȞɜȽȗɛșȾȪȹȢȳȨ
ȗǿ
Pay sufficient care not to catch the temperature sensor
with the air filter.
2
าᜤ
2
NOTE
ɲɬʟɭʵʉɥ۶ȬȻѼ᎔بȟҋȪɑȬǿ
The condenser is exposed when the filter is removed.
3)
˹ॴҷɥ
40
Ƈ͏˩Ɂ෩ȺᗖɔȲȺǾɲɬʟɭʵʉɥ
๎Ȭɞǿ
3)
Wash the air filter with a neutral detergent and tepid water
(not warmer than 40 degrees).
4)
ᅊ෩ȺҷɥȗํȬǿ
4)
Remove the neutral detergent using freshwater.
5)
٢᎔ሳȺɲɬʟɭʵʉɥ̔ྡȨȮɞǿ
5)
Dry the air filter using compressed air.
6)
Ѽ᎔بɁɽʽʑʽɿʟɭʽɥǾɂȤǾʠʳʁǾɲɬɶʽȺ
ຏોȬɞǿ
6)
Clean the condenser fins using a brush or a compressed air
gun.
7
า
7
CAUTION
1.
ᄻȾȲȗሥ࿎ȽȼȟоɜȽȗɛșί឴ʫɶʗɥᅔႊȪȹȢ
ȳȨȗᴥʫɶʗᅔႊᐐɥֆɓᴦǿ
1.
Protective glasses must be worn to prevent eye
damage from dust or foreign matter (those who are
wearing glasses included).
2.
ൡಽᤆᢆҰȾɲɬʟɭʵʉɥɝ͇ȤȹȢȳȨȗǿ
2.
Do not forget reinstall the air filter prior to operation.
Thermometer Sensor
Air Filter
ຣ࣊ʅʽɿ
ɲɬʟɭʵʉ
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......