177
ʚʍʐʴ̬૰ȟ॒ᛵȽȻȠ
WHEN BATTERY REPLACEMENT REQUESTED
ᴹʚʍʐʴ̬૰ਖ਼ᬲᴻ
<Procedures to Replace Batteries>
7
า
7
CAUTION
1.
NC
ໃੵоৰȺ
NC
ʫʬʴʚʍɹɬʍʡႊʚʍʐʴȝɛ
Ɇɿ˂ʦፏߦͱᏚ೫ҋႊʚʍʐʴɥ̬૰ȪȹȢȳȨȗǿ
NC
ໃȪɖৰȺʚʍʐʴɥ̬૰ȬɞȻǾʫʬʴюɁ
ʑ˂ʉȟțɞȝȰɟȟȕɝɑȬǿ
1.
Change the NC memory back-up battery and servo
absolute position sensing battery with power supplied
to the NC. If the batteries are changed with the NC
power supply turned OFF, the data stored in the
memory may be lost.
2.
ʚʍʐʴ̬૰ҰȾʫʬʴɵ˂ʓɗ
USB
ʫʬʴȽȼɁ۶о
ҋӌൡبɥΈႊȪȹǾʛʳʫ˂ʉɗʡʷɺʳʪȽȼɁʫʬ
ʴюɁʑ˂ʉɁʚʍɹɬʍʡɥɝǾίސȪȹȢȳȨȗǿ
ࣷᇋɂǾʚʍɹɬʍʡɥȶȹȗȽȗʑ˂ʉɁᆍૺȾߦȬ
ɞૺȾȷȗȹǾ͖ɥ២ȗɑȮɦǿ
2.
Before changing the batteries, save the memory data
such as parameters and programs as backup in an
external I/O device such as a memory card or USB
memory. Mori Seiki is not liable for problems that result
from destroyed programs or lost data that have not
been backed up.
3.
ʚʍʐʴȟඩȪȗտȠȺɝ͇ȤɜɟȹȗɞȦȻɥᆬᝓȪ
ȹȢȳȨȗǿʚʍʐʴɁտȠȟᣡȾȽȶȹȗɞȻǾ
NC
ໃȪɖȾǾʫʬʴюɁʑ˂ʉȟțɞԲ᪙ॴȟȕɝɑ
Ȭǿ
3.
Always ensure that the polarity of the batteries is
correct. If the polarity is reversed, the memory data
may be lost when turning OFF the NC power.
1)
ʚʍʐʴɵʚ˂ɥ۶Ȭǿ
1)
Remove the battery cover.
2)
ȪȗʚʍʐʴȻ̬૰Ȭɞǿ
2)
Replace the old batteries with new ones.
3)
ໃੵоৰȺҤॅᄷʓɬɥᩒȤɞǿ
3)
Open the electrical cabinet door with the main power ON.
1
1
“Opening/Closing Electrical Cabinet Door” (page 152)
4)
ʚʍʐʴȟඩȪȢ̬૰ȨɟȲȦȻɥᆬᝓȬɞȲɔȾǾʚʍ
ʐʴʦʍɹʃᑔᬂȺʚʍʐʴɁ٢ɥລްȬɞǿ
4)
In order to confirm the changing of batteries correctly,
measure the voltage on the back of the battery box.
•
ɿ˂ʦፏߦͱᏚ೫ҋႊʚʍʐʴᴷ
DC4 V
x
SERVO Absolute Position Sensing Batteries: DC4 V
• NC
ʫʬʴʚʍɹɬʍʡႊʚʍʐʴᴷ
DC4 V
x
NC Memory Back-Up Batteries: DC4 V
5)
Ҥॅᄷʓɬɥᩐɔɞǿ
5)
Close the electrical cabinet door.
1
1
“Opening/Closing Electrical Cabinet Door” (page 152)
6)
ʚʍʐʴɵʚ˂ɥɝ͇Ȥɞǿ
6)
Remount the battery cover.
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......