ҏ࿎իȾᩜȬɞɬʳ˂ʪ
ALARM RELATED TO TURRET
204
Yes
Yes
Yes
No
No
No
Yes
No
No Recovery
Recovery
Recovery
Recovery
Recovery
No Recovery
No Recovery
No Recovery
Display diagnostic screen.
Contact the Mori Seiki Service Department for assistance.
Confirm that the unclamp output signal (Y45) is ON
and unclamp completed (M1759) is Off.
Relay (KS14) or solenoid valve (YV81) wiring
disconnection?
Relay (KS13) or solenoid valve (YV80) wiring
disconnection?
Confirm that the clamp output signal (Y44) is ON
and clamp completed (M1758) is Off.
Is the unclamp completed
input signal (X4D) ON on
the diagnostic screen?
Repair or
replace
damaged parts.
Confirm proximity switch
(SQ214) operation, and
adjust or replace as
necessary.
Confirm proximity switch
(SQ14) operation, and
adjust or replace as
necessary.
Is the clamp completed
input signal (X4C) OFF
on the diagnostic screen?
Repair or
replace
damaged parts.