ʎ˂ʵʡʴʅʍʉʃʉɮʳʃʠʶ˂ɹʃʐʪɁ̬૰
TOOL PRESETTER STYLUS BREAK STEM REPLACEMENT
228
3)
ࡾщɁҏаɥʃʉɮʳʃɁ
Z
ᢉʡʳʃտϫɁᬂȾሉӦ
ȪǾʃʉɮʳʃȾ᜔ȬɞᄽҰȺඨɔɞǿ
3)
Move the tool tip to the positive direction contact face of the
stylus in the Z-axis direction and stop it immediately before
the contact.
1
ҝёൡಽͽᝢం
“
ਖ਼Ӧൡюʎ˂ʵʡʴʅʍʉɬ˂ʪ
ᴥᅔᑱࣻᴦ͇ȤǾ۶Ȫਖ਼ᬲ
”
1
Refer to the separate volume, OPERATION MANUAL
“Installing and Removing the Manual In-machine Tool
Presetter Arm (Detachable Type)”
4)
ʃʉɮʳʃɥ˨˩ȨȮǾࡾщɁҏаȟʃʉɮʳʃɁ᜔ᬂ
Ɂᅊɦ˹ȾȢɞɛșȾᝩȬɞǿ
4)
Move the stylus in the Up/down direction to bring the tool tip
to the center of the contact face of stylus.
5)
M3
Ɂфᜏሰ͇Ƞඨɔɀȫɥ፻ɔɞǿ
5)
Tighten the M3 socket set screw.
ᴹوᢆտɁᝩᴻ
<Angular Adjustment>
1)
ʨɺʗʍʒʃʉʽʓȽȼɥΈႊȪȹǾʊɮʮʵɼ˂ʂɥҏ
࿎իȾɝ͇Ȥɞǿ
1)
Fix a dial indicator on the turret, e.g. by using a magnet
stand.
2)
ʊɮʮʵɼ˂ʂɥ
X
ᢉʡʳʃտϫȞɜǾʃʉɮʳʃɁϫ
ᬂȾछȹɞǿ
2)
Bring the stem of the dial indicator into contact with the side
face of the stylus from the positive direction of the X-axis.
3)
ҏ࿎իɥʙʽʓʵᣞɝȺ
Z
ᢉտȾሉӦȨȮǾʃʉɮʳʃ
ȟ
Z
ᢉȾࢲᚐȪȹɝ͇ȤɜɟȹȗɞȞᆬᝓȬɞǿ
3)
Move the turret in the Z-axis direction by handle feed
operation to check if the stylus is set parallel to the Z-axis.
2
าᜤ
2
NOTE
ʊɮʮʵɼ˂ʂɁᦉɁӦȢᦀȟǾ
0.005 mm
͏юȞȼșȞᆬᝓȪ
ȹȢȳȨȗǿ
The allowable maximum inclination is 0.005 mm over the entire
length of the stylus side face.
Lever Type Dial Test Indicator
ȹȦࣻʊɮʮʵɼ˂ʂ
M3 Hexagon Socket Set Screw
M5 Hexagon Socket Set Screw
M3
фᜏሰ͇Ƞඨɔɀȫ
M5
фᜏሰ͇Ƞඨɔɀȫ
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......