ᯚ٢ɹ˂ʳʽʒᚽᏚᴥɴʡʁʱʽᴦ
HIGH PRESSURE COOLANT UNIT (OPTION)
166
19-5
ᯚ٢ʧʽʡɁบ̬૰Ȼ
V
ʣʵʒɁཟ೫
High Pressure Pump Oil Replacement and V-Belt Inspection
ᴹਖ਼ᬲᴻ
<Procedure>
1)
ʴʮɵʚ˂ɥ۶Ȭǿ
1)
Remove the rear cover.
8
ឬ֖
8
WARNING
ʴʮɵʚ˂ɥɝ۶ȬҰȾໃɥȪɖȪȹȢȳȨȗǿ
ᵘ̷ᡵ̜ǾൡಽɁ᪩ᵚ
Prior to removing the rear cover, turn OFF the main
power.
[Serious injury, machine damage]
2)
V
ʣʵʒɁᐗǾϾǾɒȟȽȗȞཟ೫Ȭɞǿ
2)
Check for wear, damage and loose of the V-belt.
3)
॒ᛵȾख़ȫȹ
V
ʣʵʒɁएɝɥᝩȬɞǿ
3)
If necessary, adjust the V-belt tension.
4)
ʓʶʽʋʯ˂ʠɥࣔบՙȤȾоɟɞǿ
4)
Place the drain tube in a drain pan.
5)
ʓʶʽʡʳɺɥߵȪȭȷᩒȠȽȟɜʉʽɹюɁบɥȢǿ
5)
Drain oil in the tank by slowly opening the drain plug.
6)
ፈบՠʡʳɺɥᩒȤɞǿ
6)
Open the fill port plug.
7)
บᬂɥᆬᝓȪȽȟɜบɥาȣǿ
7)
Pour oil while checking the oil level gage.
1
บɁሗ᭒ɗਖ਼ᬲɁᝊጯɂᯚ٢ɹ˂ʳʽʒᚽᏚ͇ࠖɁͽᝢ
ంɥՎྃȪȹȢȳȨȗǿ
1
For oil type and further details of the procedure, refer to the
operation manual provided with the high pressure coolant
unit.
Oil Level Gage
Rear Cover
Drain Plug
Drain Tube
Fill Port Plug
V-Belt
บᬂ
ʴʮɵʚ˂
ʓʶʽʡʳɺ
ʓʶʽʋʯ˂ʠ
ፈบՠʡʳɺ
V
ʣʵʒ
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......