B-38 MANUAL OPERATION
8-2
Indexing the Turret After Setting the Target Station Number
The turret head is indexed in manual operation when mounting and removing tools, and to
measure tool compensation values.
1)
Place the DOOR INTERLOCK key-switch in the
NORMAL
position.
2)
Close the front door.
3)
Place the PANEL key-switch in one of the positions
indicated below.
(ON)
(PANEL/EDIT)
4)
Select any of the following modes with the mode
selection switch.
(H)
(JOG)
(RPD)
(ZRN)
5)
Press the turret station setting switch
(increase) or
(decrease) to set the station
number to which indexing is required as the target
position.
The set station number will blink in the left turret
display area.
6)
Press the turret indexing switch
.
The turret is indexed to the set station number.
If the indexing is completed normally, the station
number in the left turret display area changes from
the blinking to the continually on state.
1.
Usually, the turret is indexed to the set target
station in the normal rotation.
2.
If the turret indexing switch
is not
pressed within 15 seconds after the set
station number starts blinking, the current
station number is lit continuously.
DOOR INTERLOCK
NORMAL
RELEASE
ON
PANEL
/EDIT
OFF
PANEL
MEM
MDI
TAPE
EDIT
H
JOG
RPD
ZRN
NOTE