DOOR INTERLOCK FUNCTION P-29
5)
After completing the necessary work, set the door
interlock function ON.
a)
Place the DOOR INTERLOCK key-switch in
the
NORMAL
position.
b)
Return the single block function to invalid if the
operation has been executed with the single
block function set ON.
c)
Close the door by executing M86 (door close
command) or by pressing the AUTOMATIC
DOOR CLOSE switch.
The door is locked.
This door closing operation is not necessary if the
program begins with the door close command
(M86).
5-2-4
Emergency Stop and Door Unlock (Automatic Door Type)
When the machine enters the emergency stop state, the door is placed in the unlocked state.
When the emergency stop state is reset while the door is closed (not locked), the door is locked.
If the emergency stop state is reset while the door is open, the following message is
displayed.
"EX4002 OPEN THE DOOR THEN CLOSE"
In this case, the alarm is released when the door is closed and locked by pressing the
AUTOMATIC DOOR CLOSE switch.
DOOR
INTERLOCK
NORMAL
RELEASE
NOTE
NOTE