OPERATION PANELS A-43
5-12
Rapid Traverse Rate Override Switches
The rapid traverse rate override switches are used to
adjust rapid traverse rate.
For example, these switches are used when a tool is
moved at a rapid traverse rate in test cutting.
During test cutting, although positioning is specified at a
rapid traverse rate, positioning must be executed at a
relatively slow feedrate to ensure safe operation. The
switches are used in such a case to lower axis feedrate
when executing positioning while checking axis feed
operation.
Switch operation is impossible with the PANEL
key-switch placed in the
(OFF) position.
Rapid traverse rate is adjusted in two steps,
(fine feed) and
(slow feed), taking the set
traverse rate as 100%.
1.
When the power is turned on,
(fine feed) is selected to ensure safety.
2.
For manual operation, even if the rapid override is set to 100%, the actual override
value is fixed at 50%.
3.
The rapid traverse override function is valid in the dry run mode.
4.
When the operation mode is changed from automatic to manual,
(fine feed) is
selected to ensure safety.
5-13
Handle Switches
The handle switches - which comprise the axis selection
switch, the axis feed amount selection switches, and the
manual pulse generator - are used to carry out handle
feed operations.
Close the front door before carrying out the
handle feed operation.
2
100%
1
NOTE
1
2
NOTE
1
1
x1
x10
x100
Axis selection
switches
Axis feed amount
selection switches
Manual pulse
generator
NOTE