A-54 OPERATION PANELS
5-27
Loader Valid Switch (Loader
Specification)
The LOADER VALID switch is provided on the option
panel for the loader specification machine.
It is used to make loader operation valid or invalid.
The operation is impossible with the PANEL key-
switch placed in the
(OFF) position.
5-28
Ceiling Shutter Open/Close Switches
(Loader
Specification)
The CEILING SHUTTER OPEN/CLOSE switches are
provided on the option panel for the loader specification
machine.
They are used to open/close the ceiling shutter manually.
Before opening/closing the ceiling shutter, make sure that the shutter can be opened or
closed without interference.
If the ceiling shutter is operated (opened, closed) although there is an obstacle in the
direction the ceiling shutter is moving, it could cause damage to the ceiling shutter and
the machine.
The operation is impossible with the PANEL key-switch placed in the
(OFF) position.
Loader
Function
Valid
When the switch is pressed, the indicator in the switch is lit and loader operation
becomes valid.
Invalid
When the switch is pressed while loader operation is valid, the indicator in the
switch goes off and loader operation is invalidated.
Switch
Function
When this switch is pressed, the indicator in the switch is lit and the ceiling
shutter is opened.
When this switch is pressed, the indicator in the switch is lit and the ceiling
shutter is closed.
LOADER
VALID
NOTE
CEILING
SHUTTER
OPEN
CEILING
SHUTTER
CLOSE
CAUTION
NOTE
CEILING
SHUTTER
OPEN
CEILING
SHUTTER
CLOSE