E-34 PREPARATION BEFORE STARTING MASS PRODUCTION
12
WORK COUNTER/TOTAL COUNTER SETTING (OPTION)
12-1
Work Counter (Option)
The work counter is used for managing tool lives as well as the number of workpieces machined
or to be machined.
It is possible to set whether the block delete function (BDT) or start interlock function
(STARTLOCK) is made valid when the M89 (count increment) command has been read as many
times as the number set for the work counter on the OPERATION PANEL screen.
Function selection key
(CUSTOM1)
[OPE. PANEL]
<When the block delete (BDT) function is selected>
The block delete function becomes valid when the M89 command is read as many times as the
number set for the work counter.
If the
(START) switch is pressed again, the program is executed; however, the
counter is not incremented.
<When the start interlock (START LOCK) function is selected>
When the M89 command is read as many times as the number set for the work counter, the
program is executed to the end, and then the machine stops.
If the
(START) switch is pressed again, an alarm message is displayed on the screen
and program operation is disabled.
For the procedure of specifying the M89 command, refer to the PROGRAMMING
MANUAL published separately.
NOTE
NOTE