P-14 DOOR INTERLOCK FUNCTION
4-2
Door Interlock Function of Automatic Door
The specifications of the available door interlock function for the machine equipped with the
automatic door are explained in details below along with the procedure for using the door interlock
function.
The automatic door is optional. When the machine is equipped with the automatic door,
the door interlock function operates in different manner between the machine not
equipped with a robot (operation is assumed to be performed by an operator) and the
machine equipped with a robot (operation is assumed to be performed by the robot).
Refer to the manual dealing with the machine of the same type as installed to the
customer's shop.
4-2-1
For the Machine not Equipped with Robot
The specifications of the available door interlock function for the machine equipped with the
automatic door (without robot), which is assumed to be operated by an operator, are explained in
details below along with the procedure for using the door interlock function.
<Manual operation (door interlock function valid)>
<Automatic operation (door interlock function valid)>
If the DOOR INTERLOCK key-switch is placed in the
NORMAL
position
while the door is open, only the following manual operations are
permitted.
1.
Inching and IN/OUT operation of the tailstock spindle (tailstock
specification)
When holding a workpiece using the tailstock, do not move
the tailstock spindle out in the tailstock spindle "out"
operation without first making sure that your hand will not be
caught by the tailstock spindle. If the tailstock spindle is
moved out without taking adequate care, there is a danger
that your hand will be caught between the tailstock spindle
and the workpiece.
2.
Clamp/unclamp operation of the chuck
All operations are enabled when the door is closed.
If the DOOR INTERLOCK key-switch is placed in the
NORMAL
position, automatic operation can be executed even while the door is
open. However, the codes executable with the door opened are
restricted to M00, M01, M02, M30, and automatic door open/close M
codes (M85/M86), and other M codes, S codes, T codes and axis
movement commands cannot be executed unless the door is closed.
NOTE
DOOR
INTERLOCK
NORMAL
RELEASE
CAUTION
DOOR
INTERLOCK
NORMAL
RELEASE