4.0 OPERATION
absorption stage for 3 or 4 hours before transitioning to the
float stage.
Equalize (flooded battery type only)
If the auto-equalize feature is enabled, the SS-MPPT
will equalize a flooded battery for three (3) hours every 28
days. Equalize charging raises the battery voltage above
the standard absorption voltage so that the electrolyte
gasses. This process prevents electrolyte stratification and
equalizesthe individual cell voltages within the battery.
WARNING: Risk of Explosion
Equalizing vented batteries produces explosive gases.
The battery bank must be properly ventilated.
CAUTION: Equipment Damage
Excessive overcharging and gassing too vigorously
can damage the battery plates and cause shedding of
active material from the plates. An equalization that is
too high or for too long can be damaging. Review the
requirements for the particular battery being used in
your system.
AVERTISSEMENT: Risque d’explosion
Les batteries à évent et compensation produisent des
gaz explosifs. Le groupe de batteries doit être correcte
-
ment ventilé.
PRUDENCE: Endommagement de l’équipement
Une surcharge excessive et un dégagement gazeux
trop vigoureux peuvent endommager les plaques de
batteries et provoquer l’élimination du matériau actif des
plaques. Une compensation trop élevée ou trop longue
peut provoquer des dégâts. Examinez les exigences
pour la batterie particulière utilisée dans votre système.