MORNINGSTAR CORPORATION
19
3.0 INSTALLATION
18
Choose Regulation Method (optional)
Choose between
Pulse Width Modulation
(PWM) charging
or
Slow Switching
charging. PWM charging is the default
regulation method and is the method recommended for most
systems.
Slow Switching
regulation should only be selected if noise
or interference exists in the system due to PWM charging.
This regulation method limits the switching frequency to 10
Hz (maximum), which can eliminate noise issues in some
systems.
PWM charging is selected by default. To enable
Slow
Switching
regulation do the following:
1. Remove all four screws that secure the faceplate on
the SunSaver. See Figure 2b.
2.
Gently pry the faceplate off the SunSaver.
Occasionally, epoxy encapsulant will cause the
faceplate to stick. Use a small flat-head screw driver
to separate the faceplate from the SunSaver body.
See Figure 2c.
3. A loop of wire protrudes from the epoxy. Cut the loop
with wire clippers to switch the regulation method to
Slow Switching. See Figure 2d.
4. Tape the cut ends with electrical tape to prevent
contact with the faceplate.
5. Replace the faceplate and secure with the four
screws.
Figure 2b. Remove faceplate screws.
Figure 2c. Remove faceplate.
CUT
Figure 2d. Cut the Regulation Select wire loop.
2
3 .0