2-57
10.4 STARTING ENGINE WITH BOOSTER CABLE
If the battery is discharged and booster cables are used to start the engine, do
as follows
• Be careful not to let the normal machine and problem machine
contact each other.
• When connecting the cables, never let the positive (+) and negative
(-) terminals contact each other.
• Make sure that there is no mistake in the booster cable connection.
When the final connection is made to the negative (-) terminal,
sparks will be generated, so do not connect to the negative (-)
terminal of the battery on the problem machine. Connect to the
engine block.
• When starting the engine with a booster cable, always wear safety
glasses.
NOTICE
• The size of the booster cable and clip should be suitable for the battery capacity. Check that they are not
corroded or damaged.
• The battery on the normal machine must be the same capacity as that on the problem machine.
[1] CONNECTING THE BOOSTER CABLES
★
The numbers in the diagram on the right show the order for
connecting the cables.
1. Make sure that the starting switches of the normal machine and
problem machine are both at the OFF position.
2. Connect the clips at the ends of booster cable
A
to the positive (+)
terminal of the problem machine and the normal machine.
3. Connect one clip of booster cable
B
to the negative (-) terminal of the
normal machine.
4. Connect the other clip of booster cable
B
to the engine block of the
problem machine.
5. Start the problem machine.
[2] DISCONNECTING THE BOOSTER CABLE
★
The numbers in the diagram on the right show the order for
connecting the cables.
When the engine on the problem machine starts, remove the cables in
the reverse order to connecting.