14
Follow the two maintenance steps below after
every use.
1.
Switch the cleaner off and unplug from the
socket. If the appliance was used as a steam
cleaner, place immediately on a suitable surface
(eg. tiled floor) where the residual heat/moisture in
the floor nozzle/cloth will not affect the surface.
Wait until the cleaner has cooled down
completely.
2.
Remove the detachable water tank
(1)
by
squeezing the water tank release button
(19)
. Lift
the filler cap
(2)
, and empty the water tank.
Cleaning the boiler
When the boiler requires descaling, the descaling
indicator
(29)
will illuminate. When this happens,
the boiler must be manually rinsed out with clean
water until all the scale is removed. The indicator
light will go out only after the scale has been
removed.
WARNING: Never remove the boiler screw
(58)
when the steam generator is hot.
1
Unplug the appliance from the mains outlet and
leave to cool for two hours.
2
Remove the detachable water tank
(1)
.
3
Remove the iron by disconnecting the iron steam
supply cord
(8)
from the steam cord connection
inlet
(23)
(see step 1 of ‘Steam cleaning floors
(certain models only)’, page 10).
4
Hold the steam generator main body
(16)
firmly
with both hands and shake well.
5
Turn the steam generator main body upside-down
and pull back the boiler cap
(59)
. Unscrew the
boiler screw
(58)
with the boiler key
(57)
, which is
attached to the underside of the steam generator
main body. If the screw is a bit too tight to undo,
try using a large screwdriver or a socket and
wrench set for more leverage.
6
Hold the steam generator main body over the
sink, turn it the correct way up to empty all water
and loose scale from the boiler into the sink.
7
Using clean water, refill and empty the boiler
repeatedly until all scale has been rinsed out.
8
Replace the boiler screw, ensuring it is tightened
fully. Replace the boiler cap, boiler key, water tank
and iron to the base unit.
WARNING: Ensure the boiler is empty before
replacing the boiler screw.
9
The descaling indicator will extinguish the next
time you use the product. Please wait for up to
one minute whilst it pumps water and registers
that the boiler has been cleaned.
To clean a coated soleplate
(6)
Do not use scouring powder or solution as this
could cause damage to the coating.
If any man-made fibres fuse to the soleplate, set
the iron at the MAX position and pass it over a
clean piece of cotton to draw the deposit off the
surface.
To clean the exterior
Allow the unit to cool and wipe over with a damp
cloth and mild detergent, then wipe dry. Abrasive
cleaners should not be used.
Cleaning the cloths (certain models only)
The micro-fibre floor cloth
(55)
and the
elasticated utility cloths
(50)
can be machine
washed (40ºC max). For heavy soiling, soak the
cloths in warm water and detergent or a mild
stain remover.
IMPORTANT: Do not use bleach or fabric
softener.
Allow cloths to completely dry before storing.
Replacement cloths can be purchased by calling
our UK helpline directly on:
0844 873 0726
or
logging onto
www.morphyrichards.com
.
Maintaining the attachments (certain
models only)
Dirt and blockages should be regularly removed
from the attachments to help prolong their usage.
After use
Maintenance
57
58
59
57
58
59
RN330009MUK Rev2_Instruction Book 11/12/2013 14:57 Page 14