-  When the value scale to be measured is unknown beforehand, set 

the range selector at the highest position. 

-  Do not measure voltage if the voltage on the terminals exceeds 

1000V above earth ground. 

- Always be careful when working with voltages above 60V DC or 30V 

AC rms, keep fingers behind the probe barriers while measuring. 

- Before rotating the transform switch to change functions and ranges, 

disconnect test leads from the circuit under test. 

- Never perform resistance, transistor and diode measurements on live 

circuits. 

- Never use the meter under the condition of the explosive air, steam 

or dirt. 

- If any faults or abnormalities are observed, the meter cannot be used 

any more and it has to be checked out. 

-  Never use the meter unless the rear case is in place and fastened 

fully. 

- Please do not store or use meter in areas exposed to direct sunlight, 

high temperature, humidity or condensation. 

 

 

SYMBOLS 

 Important safety information, refer to the operating manual. 

  Double insulation

Protection class

ΙΙ

CAT 

ΙΙ

  Overvoltage (Installation) category II, Pollution Degree 2 per 

IEC1010-1 refers to the level of Impulse Withstand Voltage 

protection provided. 

CAT 

ΙΙΙ

  Overvoltage (Installation) category III, Pollution Degree 2 per 

IEC1010-1 refers to the level of Impulse Withstand Voltage 

protection provided. 

  High voltage warning symbol 

  Conforms to european union directive 

Earth ground 

  Fuse 

- 2 - 

  Alternating current 

  Direct current 

 

Diode 

H This indicates that the display data is being held. 

  The battery is not sufficient for proper operation.   

 

 

MAINTENANCE 

-Please do not attempt to adjust or repair the meter by  removing the 

rear case while voltage is being applied. A technician who fully 

understands the danger involved should only carry out such actions.   

-  Before opening the battery cover or case of the meter, always 

disconnect test leads from all tested circuits.   

-  To avoid the misreadings, when the meter  displays“

”, you must 

change the battery. 

-  For continued  protection against fire, replace fuse only with the 

specified voltage and current ratings: F 200mA/250V (quick acting). 

- Do not use abrasives or solvents on the meter; use a damp cloth and 

mild detergent only. 

-  Always set the power switch to the OFF position when the meter is 

not in use. 

-  If the meter is to be stored for a long period of time, the batteries 

should be removed to prevent damage to the unit. 

 

DESCRIPTION 

-  This meter is a portable professional measuring instrument with a 

handsome LCD for easy reading. 

-  Single operation of the  transform switch makes measurement 

convenient. Overload protection and low battery indication are 

provided. This meter is ideal for use in the fields, workshop, school, 

hobby and home applications. 

- This meter includes the data hold function. 