- Connect the red lead to the anode, the black lead to the cathode of
the diode under testing.
- You can get reading from LCD.
NOTE:
- The meter will show the approximate forward voltage drop of the
diode.
- If the lead connection is reversed, only figure ‘1’ will be displayed.
- When the input is not connected, i.e. at open circuit, the figure ‘1’ will
be displayed.
•
TESTING TRANSISTOR
- Set the transform switch at the hFE range position.
- Identify whether the transistor is NPN or PNP type and insert emitter,
base and collector leads into the proper holes of the transistor on the
socket for testing.
- You can get reading from LCD.
MAINTENANCE
●
BATTERY REPLACEMENT
Before attempting to open the battery cover of the meter, be
sure that test leads have been disconnected from
measurement circuit to avoid electric shock hazard.
WARNING
- Loosen the screw fixing the battery cover and remove it.
- Replace the exhausted battery with a new one.
- Replace the battery cover.
●
FUSE REPLACEMENT
- Loosen the screw fixing the battery cover and remove it.
- Replace the blown fuse with ratings specified.
- 10 -
- Replace the battery cover.
Before attempting open the battery cover of the meter, be sure
that test leads have been disconnected from measurement
circuit to avoid electric shock hazard.
WARNING
For protection against fire, replace fuses only with specified
ratings: F 200mA/250V (quick acting).
●
TEST LEADS REPLACEMENT
Full compliance with safety standards can be guaranteed only
if used with the test leads supplied. If necessary, they must be
replaced with the same model or same electric ratings. Electric
ratings of the test leads: 1000V 10A.
WARNING
You must replace the test leads if the lead is exposed.
ACCESSORIES
⑴
Test Leads: Electric Ratings 1000V 10A
one piece
⑵
Battery:1.5V, AAA
three pieces
⑶
Instruction Manual
one piece
- 11 -