Clearance requrements
FreeSTANDiNg reSiDeNTiAL iNSTALLATiON TOp veNT
using double wall connector
USA
Canada
A. Sidewall to unit
15”
381 mm
B. Backwall to unit
1”
26 mm
C. Cornerwall to unit
2½”
64 mm
D. Sidewall to connector
21”
533 mm
E. Backwall to connector
7”
178 mm
F. Cornerwall to connector
8½”
216 mm
G. Unit to ceiling
47”
1194 mm
Backwall
Sidewall
Sidewall
Floor protection requirements
NON -COMBUSTiBLe MATeriAL BeNeATH STOve
USA
Canada
A. Extending distance, back
-
8’’(200 mm)
B. Extending distance, right side
6”
8’’(200 mm)
C. Extending distance, left side
6”
8’’(200 mm)
D. Extending distance, front
16”
18’’(450 mm)
US:
FLOOr prOTeCTOr MUST Be
NON-COMBUSTiBLe MATeriAL
iT MUST eXTeND FrONT/SiDe/reAr AS iNDiCATeD
CANADA:
FLOOr prOTeCTOr MUST Be
NON-COMBUSTiBLe MATeriAL
iT MUST eXTeND FrONT/SiDe/reAr AS
iNDiCATeD
MAXiMUM ALCOve DepTH 32” (813 MM)
Clearance requrements
ALCOve iNSTALLATiON
using double wall connector
USA
Canada
A. Sidewall to unit
15”
381 mm
B. Backwall to unit
1”
26 mm
C. Cornerwall to unit
-
-
D. Sidewall to connector
21”
533 mm
E. Backwall to connector
7”
178 mm
F. Cornerwall to connector
-
-
G. Unit to ceiling
33½”
851 mm
W. Minimum alcove width
-
-
D. Maximum alcove depth
32”
813 mm
G. Alcove ceiling above stove top
33½”
851 mm
Floor protection