Mobile Home installation
The Morsø 7600 can be installed in a mobile home if equipped with an outside combustion air kit, a
terminal cap with a spark arrestor, and if it meets the following installation requirements:
•
The stove must be secured to the mobile home structure by bolting through the hearth pad and
into flooring.
7642 & 7644 are prepared for securing.
The 7648 requires you drill three holes in the floor at specific points (see diagram below).
•
The stove must be installed with a listed Type HT chimney connector, HT Chimney, and termi
-
nal cap with spark arrestor. Never use a single wall connector (stovepipe) in a mobile home
installation.
•
Floor protection requirements in section 1.5 must be followed precisely.
•
In Canada, this appliance must be connected to a 6” (152 mm) factory-built chimney confor
-
ming to CAN/ULC-629M, STANDARD FOR FACTORY BUILT CHIMNEYS. Floor protection as
referenced in section 1.5 must be followed, as well as use of Canadian Floor Protector.
•
Follow the chimney and chimney connector manufacturer’s instructions when installing the
flue system for use in a mobile home.
•
Intake air piping can be installed through the floor into a vented crawl space or through the
wall of the residence to obtain outside air.
•
Install in accordance with 24 CFR, Part 3280 (HUD).
•
NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5” from
ground level for transportation purposes.
3
8
"
8 mm
3
8
"
8 mm
3
8
"
8 mm
0
3
7
8
"
97 mm
7
5
8
"
195 mm
0
6
5 8
"
168 mm
6
5 8
"
168 mm
Revisions
Rev.
Sign.:
Title:
Drawing no.:
Dim. without indication of margin acc. to DS/ISO 2768-1 m
1:2.5
Boreanvisning for evt. fastmontering
Drilling instructions for potential fixing
Morsø 7600
RSV
21.11.2008
A3
Work up Drawing
9,98 kg
Cast Iron GG15
Date of print: 29-09-2010
C:\UDV\tegninger\7600\7600-16 Pedistalfod.SLDPRT
7616
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date:
Borefixturer:
7600-16 a
Page: 3
WArNiNg:
Never DrAW COMBUSTiON Air FrOM A WALL, FLOOr Or CeiLiNg CAviTy Or FrOM ANy eNCLOSeD
SpACe SUCH AS AN ATTiC Or gArAge.
DO NOT iNSTALL iN A BeDrOOM Or A rOOM WHere peOpLe SLeep.
CAUTiON:
THe STrUCTUrAL iNTegriTy OF THe MOBiLe HOMe FLOOr, WALL, AND CeiLiNg/rOOF MUST Be
MAiNTAiNeD (i.e., DO NOT CUT THrOUgH FLOOr JOiST, WALL STUD, CeiLiNg TrUSS, eTC.)
Acid protection
If acid-washing the masonry around the stove, protect the stove surface with an acid-proof cover.
Outside Air Supply
Only mobile home approved heaters may be installed into mobile homes and it is a requirement that
outside air is supplied directly to the heater.
However, in every residential situation where the room has poor air infiltration via doorways, windows
and the like, providing a dedicated outside air supply may be required. By attaching a non-combustible
conduit (ducting) directly to the air intake of the heater, outside air can be delivered directly to the com-
bustion chamber. Some models may require an additional (optional) outside air kit. The conduit used for
providing outside air should have a free space equal to but no less than 3” diameter.
Outside air is particularly important when the heater is to be installed into a well sealed room, or where
an extractor hood or ventilation system interferes with the room’s natural air pressure. Avoid placing
the outside air supply onto a wall that that is usually subject to negative pressure from normal wind
pattern.
A
A
A-A
STORM COLLAR
EMBASE TEMPÉTE
SPARK ARRESTOR
PARE ÉTINCELLES
LISTED CHIMNEY
CHEMINÉE REPERTORIÉE
ROOF FLASHING/SUPPORT
SOLIN TOUT/SUPPORT
lISTED CHIMNEY
CONNECTOR
CONDUIT CHEMINÉE
RÉPERTORIE
OUTSIDE AIR
EXTÉRIEUR AIR
FLOOR PROTECTOR
PROTECTION DU SOL
Revisions
Rev.
Sign.:
Title:
Drawing no.:
1:15
Skorstenskitse
Morsø 7600
RSV
20.05.10
A4
268,91 kg
Date of print: 25-05-2010
U:\udv\Tegninger\TILBEHØR\Skorsten\Ovn med skorsten til vejledning.SLDASM
7600-125 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date: