background image

MORTEX

 

PRODUCTS

 

INC

 

FORT

 

WORTH,

 

TX

 

76106

 

Page

 

3

 

Series

Door Type

Top Cover

Cabinet Type

Cabinet Height

97-F

S = Solid

L = Louvered

O = Open

S = Solid

21 = 23 1/4"

27 = 30 1/2"

39 = 41 1/4"

B = Knocked Down

F = Assembled

 

Table 1: Coil Cabinet Model Nomenclature 
 

Front 

Door of 

Cabinet

Open 

Top 17 

3/4" x 21 

3/4"

Maximum 

Air Flow 

CFM

1" Pleated 

Air Filter, 

In The 

Door

2" Pleated 

Air Filter, 

Top of 

Cabinet

Height

Depth

Width

Louvered

N/A

1200

20x20

23 1/4"

25"

19 3/4"

Solid

1600

20x24

23 1/4"

25"

19 3/4"

Louvered

1800

20x20

20x24

23 1/4"

25"

19 3/4"

Louvered

N/A

1600

20x30

30 1/2"

25"

19 3/4"

Solid

1600

20x24

30 1/2"

25"

19 3/4"

Louvered

1800

20x20

20x24

30 1/2"

25"

19 3/4"

Louvered

N/A

1800

2ea 20x20

40 1/4"

25"

19 3/4"

Solid

2000

20x24

40 1/4"

25"

19 3/4"

Louvered

N/A

1200

N/A

N/A

18"

N/A

19 3/4"

Louvered

N/A

1600

N/A

N/A

24"

N/A

19 3/4"

Frame & Grills Non-Cabinet

Coil Sizes

All Mortex 96 series coils will fit in cabinet

 96-97 series coils and 98 series coils sizes up to 98-8W7

All Mortex series coils will fit in cabinet

 

Table 2: Optional Coil Cabinet and Return Air Grille Models, CFM’S and Air Filter Chart 
 

 

SECTION III: INSTALLING THE LOUVERED 
DOOR FRAME ASSEMBLY 

 

Alcove Installation 

 

This kit is approved for use in alcove installations with an 
approved air conditioning coil. The louvered door frame 
assemblies are available in 18 inch and 24 inch height. 
The furnace is 33” in height making the total furnace and 
filter frame assembly heights either 51 inches or 57 
inches. To install the louvered door frame assembly to 
the furnace follow the steps below’ 

 

Prior to installing the furnace make sure the holes are 
cut into the floor for the refrigerant tubing, the electrical 
wiring are in place, the thermostat wiring and the 
condenser control wiring are in place. 
1.  Before installing the coil cabinet on the furnace, be 

sure you have enough clearance to install the 
furnace and the louvered door assembly. 

2.  Remove the louvered door frame assembly from the 

box. 

3.  Remove the front access panel (door) by removing 

the thumb screw that secures the door to the frame 
assembly. 

4.  Lay the frame assembly flanges against the furnace 

top cover and align the screw holes in the furnace 
top cover with the holes in the flanges of the frame 
assembly. Refer to Figure 1. 

5.  Install the screws through the holes provided in 

order to secure the frame assembly to the top of the 
furnace.  

6.  Slide the furnace on to the floor base and follow the 

instructions in the installation manual to properly 
install the furnace. 

7.  Follow the instructions to properly install the cooling 

coil. 

8.  Install the coil air filters as shown in figure 4 
9.  Place the ½ inch flange on the bottom of the door 

into the behind the flange provided on the frame 
assembly. 

10.  Push the door towards the frame assembly, then 

insert the thumb screw into the hole provided at the 
top of the door and tighten the screw until the door is 
securely fastened to the frame assembly. 