background image

MORTEX

 

PRODUCTS

 

INC

 

FORT

 

WORTH,

 

TX

 

76106

 

Page

 

4

 

 

NOTE: The installer must provide a strap that 
attaches to the top of the furnace and is secured to 
the alcove wood framing. 

 

 

Figure 2: Return Air Grille Frame Assembly 
 
 

 

Figure 3: Return Air Grille 

 

 

Figure 4: “A” Coil Filters 
 

NOTE: Coil Filters are used with the 97-FG Frame and 
Grille assemblies only. 
 

SECTION IV: INSTALLING THE COIL CABINET 
 
Closet or Alcove Installation 

 
This kit is approved for use in an alcove or closet 
installations with an approved air conditioning coil. The 
coil cabinets are available in 23 1/4”, 30 1/2” and 40 1/4” 
height. The furnace is 33” in height making the total 
furnace and coil cabinet heights are 56”, 63” and 73”. To 
install the coil cabinet assembly to the furnace, follow the 
steps below’ 

 

Prior to installing the furnace make sure the holes are 
cut into the floor for the refrigerant tubing, the electrical 
wiring are in place, the thermostat wiring and the 
condenser control wiring are in place. 
1.  Before installing the coil cabinet on the furnace, be 

sure you have enough clearance to install the 