MOUNTING OPTIONS
You have several options when installing your ULTIMATE
1000™ LIFT. It can be mounted 1.)
STATIONARY
in a fixed
location where the machine does not move or 2.)
TRACK
or
All-
ACCESS TRACK SYSTEM
, where the lift can be moved from one
location to another location.
Either system can also be mounted
“FLUSH”
(directly against
the ceiling) or
“SUSPENDED”
(down from the ceiling to almost any
height using all thread & sway bracing, not shown in pictures).
Also, the
Freedom Pivot
can be added to both systems.
This
INSTALLATION SUGGESTION
guide explains the different
methods of installation and provides the basic guidelines of the various
types of mounting options.
DO NOT RECESS TRACK. THE LIFT WILL SCRATCH THE CEILING
WHEN UNDER LOAD IF THE TRACK IS RECESSED.
Electrical Requirements:
Electrical requirements for this machine are a
110v
15amp grounded outlet with surge protector placed within
5’ft. of
the machine.
A
standard 5ft cord
is sent pre-installed
with all stationary units.
It is highly recommended to have
the outlet, to which the machine is plugged, wired to a wall
switch for emergency shutoff purposes
.
WARNING
These instructions are recommendations only
and are intended to provide you with some basic
guidelines for installation.
We strongly urge you to verify the proposed
details of your unique installation with a local engineer
and a local building code official to verify its adequacy
and ensure compliance with local codes and
ordinances.
Summary of Contents for ULTIMATE 1000