background image

MOUNTING OPTIONS

 

 

You  have  several  options  when  installing  your  ULTIMATE 

1000™  LIFT.  It  can  be  mounted  1.) 

STATIONARY

  in  a  fixed 

location where the machine does not move or 2.) 

TRACK 

or

 All-

ACCESS TRACK SYSTEM

, where the lift can be moved from one 

location to another location.   

Either system can also be mounted 

“FLUSH”

 (directly against 

the ceiling) or 

“SUSPENDED”

 (down from the ceiling to almost any 

height using all thread & sway bracing, not shown in pictures).  
Also, the 

Freedom Pivot

 can be added to both systems. 

 

This 

INSTALLATION  SUGGESTION

  guide  explains  the  different 

methods of installation and provides the basic guidelines of the various 

types of mounting options. 

 

DO NOT RECESS TRACK. THE LIFT WILL SCRATCH THE CEILING 

WHEN UNDER LOAD IF THE TRACK IS RECESSED. 

 

Electrical Requirements: 

Electrical  requirements  for  this  machine  are  a 

110v 

15amp grounded outlet with surge protector placed within 

5’ft. of

 the machine.

  A 

standard 5ft cord

 is sent pre-installed 

with all stationary units.  

It is highly recommended to have 

the outlet, to which the machine is plugged, wired to a wall 
switch for emergency shutoff purposes

 
 

 

 

 

WARNING

 

These instructions are recommendations only 

and are intended to provide you with some basic 

guidelines for installation. 

We strongly urge you to verify the proposed 

details of your unique installation with a local engineer 

and a local building code official to verify its adequacy 

and ensure compliance with local codes and 

ordinances.

 

Summary of Contents for ULTIMATE 1000

Page 1: ...Installation Suggestions ...

Page 2: ...the various types of mounting options DO NOT RECESS TRACK THE LIFT WILL SCRATCH THE CEILING WHEN UNDER LOAD IF THE TRACK IS RECESSED Electrical Requirements Electrical requirements for this machine are a 110v 15amp groundedoutlet with surge protector placedwithin 5 ft ofthemachine Astandard 5ft cord is sent pre installed with all stationary units It is highly recommended to have the outlet to whic...

Page 3: ...le the machine isstillon the ground plugthe machine in and unwind straps until fully extended 4 Flip the machine so that the motor and components are touching the floor 5 Connect extended straps to eye bolts and lift the hoist to the ceiling by pressing the up button on the remote or pendant this keeps the hooks on the machine from jamming or catching in the machine spools whilelifting Be sure the...

Page 4: ...th corner until the metal washer is firm against the frame and does not rattle A good method is to make this adjustment while the motor is in operation When in perfect alignment the motor will run smoothly and quietly C Insert and tighten the center 2 lag screws until the metal washer touches the frame and does not rattle Suspended Monorail Track Mount on a WoodJoistCeiling Mounted Perpendicular t...

Page 5: ...base Slotted Holes Used for Stationary mounting with Lag Bolts or All Thread 10 Slotted holes 5 on each side of the machine 2 End Slots are 16 on center Slots are 2 Long X 9 16 Wide Slots are from Long Edge of the machine 16 on Center 2 End slots and Center Slot are 16 on Center length 32 ...

Page 6: ...Rev 4 5 2021 M ORTUARY LIFT COMPANY THE ULTIMATE 1000 LIFT 127Cottage Grove Avenue S E Cedar Rapids Iowa 52403 800 628 8809 319 364 4910 www mortuarylift com ...