21/1
1/19 CD5R9013_EN finire m0
ENGLISH
ENGLISH
M
21
STARTING AND STOPPING
(DIESEL ENGINE)
REV
.0-1
1/19
STARTING
1) make sure the load plugs are di
-
sconnected or that the main switch
of machine is open (lever facing
down), so as to ensure the motor’s
start-up without any loads inserted.
NOTE
Do not alter the primary conditions of regulation and do not
touch the sealed parts.
!
Check daily
TEMPERATURE
TIME
≤
- 20
°
C
5’
- 20
°
C / - 10° C
2’
- 10
°
C / - 5° C
1’
≥
- 5
°
C
20”
2) Turn the starter key to position “ON”. Make sure the battery
charge and oil warning lights are lit
3) Turn the start-up key (Q1) to the START position, once the
engine is started up leave the key, it will reposition itself in
“ON”.
In case of unsuccessful start-up, do not insist for longer
than 5 seconds. Wait 10 seconds before attempting
another start-up.
4) The engine starts up at its operating speed. After start-up,
allow the engine to run for a few minutes before powering
on the utilities. See table.
5) Start-up at low temperatures.
The motor will normally start up without problems down to
temperatures of -10° C.
For start-up and use at lower temperatures please see the
engine manual or turn to our Technical Assistance Center.
ENGINE PROTECTION
The generator is equipped with protection
(engine stop) for low oil pressure and high
temperature.
The engine protection is signaled by the
lights (O1) (F5).
The battery indicator light, indicates a fault
without stopping the engine.
STOPPING
Under normal conditions, use the following procedure:
1) stop the power source, turning off the connected equipment,
if they do not have a power switch, open the main switch of
the machine (lever facing down)
2) allow the engine to run without any load for a few minutes
3) turn the starter key (Q1) to the
position OFF.
EMERGENCY SHUTDOWN
To shut down the engine in an emergency situation act imme
-
diately on the stop lever or the key (Q1) to the OFF position.
CAUTION
RUNNING-IN
During the first 50 hours of operation, do not use more than
60% of the maximum output power of the unit and check the
oil level frequently, in any case please stick to the rules given
in the engine use manual.
!