DSP 2x400 PS-PL
REV.0-11/05
M
1.6
TECHNICAL DATA
28/11/05 78413-GB
C.C. WELDING
Welding current
2x400A/35% - 2x360A/60% - 2x330A/100%
Starting voltage
68V
C.V. WELDING
Welding current
2x360A/60% - 2x330A/100%
Welding voltage
16 - 36V
SIMULTANEOUS UTILIZATION FACTORS
In case
Welding
and
Generation
can be used simultaneously, however, the engine
cannot
be overloaded.
The table below gives the maximum limits to be respected:
STATIC CHARACTERISTIC
100
200
300
400
500
A
V
10
20
30
40
50
60
70
10
min.
max
C.V.
C.C. TIG
C.C.
C.C.
C.C.
35 kVA
30kVA
25kVA
AUXILIARY POWER
300A
400A
WELDING CURRENT
SINGLE POSITION
0
200A
100A
40 kVA 40 kVA
2x300A
2x400A
0
2x200A 2x100A
WELDING CURRENT
DOUBLE POSITION
30 kVA
20 kVA
10kVA
40 kVA 40 kVA
AUXILIARY POWER