OPERATION
Page 17 of 23
5) If burner does not stay lit, repeat steps 3 and 4 after
5 minutes.
6) If burner still does not stay lit, then:
a) Push in gas control knob and turn counter clockwise
to the
“
LOW” position.
b) Keep depressing the control knob, put long stem
lighter into the ignition hole on the emitter screen to
light the burner.
c) Repeat step 4.
7) Turn the control knob counter clockwise to “HIGH”
position. If you want a lower temperature, turn the
control knob clockwise to the “LOW” position.
Flame Characteristic
The flame pattern at the emitter screen should be visually
checked whenever heater is operated. Normally the burner
flame is blue, but a small yellow flame is acceptable.
If flames extend beyond surface of the emitter grid, or the
phenomena of flame lift or light back, or black spot is
accumulating on the emitter grid or reflector, the heater
should be
TURNED OFF
immediately. The heater should
not be operated again until the unit is serviced and or
repaired.