Appendix F: Redundant Backup with TP64 and TPT-2 Transfer Panels
F-3
Moseley SL9003Q
602-12016-01 Revision J
The digital audio (AES/EBU) or analog audio lines can be split to both of the program inputs
through the use of wired XLR tees.
NOTE
: The transmitter audio encoder input impedance default is 10K Ohms so
paralleling the inputs with the tee is acceptable. If 600 Ohm termination is preferred,
internal jumpers E2 and E5 must be set to 600 Ohms on the audio encoder of either the
main or the backup link but not both. Installing 600 Ohm termination will lower the audio
level by 6 dB.
The RS-232 data control aux channel can be split to both transmitters through a “modem
splitter”. The splitter can be a passive device, such as Black Box P/N TLO73A-R2 (3 port,
MS-3).
Figure F-1. Starlink SL9003Q with TP128 Transmitter Main/Standby Configuration