F.6 Software Settings
The full array of available settings for the Control and Configuration menus are located in
QAM User Manual. The applicable settings for redundant standby systems are shown here.
F.6.1 Starlink Transmitter Settings
These settings configure the transmitter for hot (or cold) standby. It is important that each
Starlink transmitter in the redundant pair is configured identically for proper operation.
Controls #1
TX CONTROL
:
XFER:
Configures the unit for HOT or COLD STANDBY operation,
depending on the setting of TX XFER (next line in menu).
TX XFER
: (select per system requirement)
HOT:
Configures the unit for HOT STANDBY operation.*(preferred)
COLD:
Configures the unit for COLD STANDBY operation.
TX STATUS
: (shown in this menu for ease of use)
RADIATE: Indicates the transmitter is ON and radiating
OFF:
Indicates the transmitter is OFF
F.6.2 TP128 Settings
The TP128 software settings are contained in the internal firmware. Please consult the
TP128 manual for further details.
F.6.2 TP64 Settings
The TP64 software settings are contained in the internal firmware. Aside from the front
panel RADIO A/B Master Select (described above), there are no user-configurable settings
in the TP64 unit.
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...