Section 4: Operation
4-13
Moseley SL9003Q
602-12016-01 Revision J
4.4.9 System: Transfer
Function Settings
Summary
Tx Transfer
HOT
COLD
OFF
For external transfer panel setups (see Appendix F)
-Both TX on
-Shuts PA off during standby
-none
Rx Transfer
ON / OFF
enables RX transfer
4.4.10 System: External I/O (NMS)
Function Settings
Summary
Ext A/D
Readings:
#1- 0.00
#2- 0.00
#3- 0.00
#4- 0.00
Monitors analog inputs #1, #2, #3, and #4 dc
levels.
(on pins 14, 13, 12, and 11, respectively of Ext I/O
high-density connector).
Ext Status
Readings:
#1- OFF
#2- OFF
#3- OFF
#4- OFF
Monitors digital inputs #1, #2, #3, and #4 logic
levels.
(on pins 18, 17, 16, and 15, respectively of Ext I/O
high-density connector).
Ext Relays
RELAY CONTROLS
MAP FAULTS-RELAYS
-Map to Relays? OFF/ON
Relay Controls: Manually force relay contacts
closures for external relays #1,#2, #3, and #4.
Map Faults-Relays: Maps fault logic to contact
closures for ext. relays #1-#4.
(on pin pairs 8-7, 6-5, 4-3, and 2-1 of Ext I/O high-
density connector).
Ext D/A
OUTPUT *RX SIG LVL
OUTPUT *TX FWD PWR
OUTPUT *Rev PWR
OUTPUT *BER
Controls monitoring output source of pin 10 on Ext
I/O high-density connector.
Receiver: Received Signal Level 0-5 Vdc
Transmitter: Transmit Power 0-5 Vdc
Summary of Contents for Starlink SL9003Q
Page 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Page 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Page 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Page 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...